1-1
Users Manual
Custom Sensors Model CCD8000 Scanner
Introduction
The Model CCD8000 Scanner is designed for Point of Sale or Office use. Three interfaces
are provided. The Keyboard Wedge interface connects between a PC keyboard and the
computer console. When scanned, the characters in the barcode appear as though they
were typed on the keyboard. The USB interface behaves like the keyboard wedge, except it
connects to the computer through its USB port, rather than the keyboard port. The RS-232
interface can be connected to a Com: port on a PC or any other device with an EIA/TIA RS-
232C interface.
The Scanner has a wide reading aperture and is designed to operate in contact with, or
close to, the barcode symbol being scanned. The scanner can be up to ¾ inch from the
code. When the switch is pressed, the light source illuminates the barcode. The code is
read and decoded, a beeper sounds and the indicator light flashes. The illumination is then
extinguished. This process normally takes less than a second .
The unit will read barcodes up to 3 inches long. Most common linear barcode symbologies
are supported, including EAN/UPC, Code39, Code128, Codabar, Interleaved 2 of 5, Indus-
trial 2 of 5, Matrix 2 of 5, DataLogic 2 of 5, Code93, IATA, MSI/Plessey, and Code11.
Installation
The three standard interfaces, Keyboard Wedge, USB and RS-232 are accomplished
through the use of seperate cable assemblies. When a unit is ordered with one of these inter-
faces, the proper cable assembly is shipped with the unit. The cable assemblies contain a
telephone-type connector, which mates with a connector at the rear of the scanner. It is pos-
sible to change the scanners interface by changing the cable. Cables are available from
Custom Sensors.
The Keyboard Wedge Interface.
The model with the keyboard wedge interface connects between the keyboard and the
console of the computer. This model is available with two types of connectors; the 5-pin
DIN or the 6-pin mini-DIN. Both units connect in the same manner. Turn off power to the
computer. Unplug the keyboard cable. Plug the keyboard cable into the female connector
on the scanner cable. Plug the male connector on the scanner cable into the computer
keyboard connection. The scanner derives its power from the computer, so no external
power supply is necessary. Turn on the Computer. The scanner should emit an audible
tone.
To test the installation, start an application on the computer, such as a word processor,
that displays characters typed on the keyboard. Review the section on Using CCD Scan-
ners, later in this manual, if necessary. Scan the barcode below. The scanner should emit
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1 - User’s Manual

1-1User’s ManualCustom Sensors Model CCD8000 ScannerIntroductionThe Model CCD8000 Scanner is designed for Point of Sale or Office use. Three interf

Página 2 - Connector

STARTENDABORTSET2-4CFT-AENDSTARTABORTSETRS-232 ParametersTo set the Scanner to RS-232 communications, scan the code below. Note that in order forthe s

Página 4

STARTENDABORTSET2-6CFT-AENDSTARTABORTSETGeneral ParametersThis Section sets some general configuration parameters that are independent of the typeof i

Página 6 - Test Barcodes

STARTENDABORTSET2-8CFT-AENDSTARTABORTSETTrigger On / Good Read Off - The trigger switch controls the start of the reading process.When the trigger is

Página 8

STARTENDABORTSET2-10CFT-AENDSTARTABORTSETCode Type ON OFFEAN/UPC Add-onCode 128Code 11MSI/PlesseyDataLogic 2 of 5Specific UPC/EAN ParametersScanning t

Página 10

STARTENDABORTSET2-12CFT-AENDSTARTABORTSETSpecific Code 39 Parameters.This Section configures parameters associated with the Code 39 barcode type.There

Página 12

1-2a tone. The characters in the barcode should appear as though they were typed on the key-board.ConnectorWiring.SCANNER TESTThe USB Interface.The U

Página 13

STARTENDABORTSET2-14CFT-AENDSTARTABORTSETIndustrial 2 of 5 ParametersFor the Industrial 2 of 5 code type can be printed with a check digit. The scanne

Página 15 - Code Type ON OFF

STARTENDABORTSET2-16CFT-AENDSTARTABORTSETpressed as a Hexadecimal number, rather than decimal. Turn to the table in appendix A toconvert the desired l

Página 17

STARTENDABORTSET2-18CFT-AENDSTARTABORTSETAppendix AThe table below is used to convert the desired code length to a Hexadecimal number.Locate the desir

Página 19

STARTENDABORTSET2-20CFT-AENDSTARTABORTSETAppendix CAppendix C contains the Barcodes that correspond to the Hexadecimal characters. Noticethat when any

Página 20

1-3Using CCD ScannersThe CCD Scanner reads barcodes through the elongated front opening in the scanner. Thescanner is normally placed on the code so t

Página 21 - Define Length

1-4TROUBLESHOOTINGThe following items illustrate common problems encountered in the initial installation of theCCD Scanner.Common Scanning ProblemsA b

Página 22

1-5RS-232 ConfigurationThe scanner beeps and the indicator flashes, but no data seems to be transmitted.Make sure the scanner is set up as an RS-232 d

Página 23

1-6Test Barcodes1234567890Interleaved 2 of 50 12345 12345 0UPC-A2 512345 123453 EAN-13519999 781568 849294 BooklandA1234567890DCodabar 231

Página 25 - Appendix B

STARTENDABORTSET2-2CFT-AENDSTARTABORTSETThe Scanner Communications Settings.The scanner has three communications methods. The Default is Keyboard Wedg